Lithotripsy Machine

Leading Manufacturers, Exporters and Wholesaler of Astra 35W Holmium Yag Laser Lithotripsy System, Calculiclast Intra Corporeal Pneumatic Lithotripsy System and Pneulith Digital Pneumatic Lithotripsy System from Satara.

Business Type Manufacturer, Exporter, Supplier
Model No Astra-30
Application Stone Fragmentation
Brand Name Astra-35
Wavelength 2.1 micrometer
Output Energy 0.5 J to 3 J
Mode of operation Pulsed
Pulse Duration 250 to 650 microseconds
Frequency of operation 5 Hz, 10 Hz, 15 Hz & 20 Hz
Average power 30 Watt (Max.)
Aiming Beam Green
Cooling Integral water to air heat exchanger.
Beam delivery Fibre coupled
Fibre diameter 200, 273, 365, 550 µm
User interface Touch screen display
Input Power 230 volts, 50 Hz, Single phase

Click to view more

Holmium YAG Laser, being a gold standard for lithotripsy procedures, uses laser energy to precisely fragment kidney, bladder, and ureteral stones. It provides effective stone fragmentation with minimal damage to surrounding tissue, offering a versatile and safe option for urological procedures.

  • Regulatory Approval: Approved by CDSCO for manufacturing license, adhering to national regulatory requirements for medical devices.
  • Safety Compliance: Certified according to IEC 60601-1, ensuring the highest standards for electrical medical equipment safety.
  • Electromagnetic Compatibility (EMC): Meets IEC 60601-1-2 standards, guaranteeing reliable performance without interfering with other electronic devices.
  • Laser Safety: Compliant with IEC 60601-2-22, ensuring safe and effective operation of medical laser equipment.

 

Features 

  • Astra-35 is a 35W Holmium YAG Laser Lithotripter indigenously developed in India. 
  • Our experts, having more than 30 years of laser designing & manufacturing experience have put in their best to make the Ho:YAG Laser Lithotripter a world class product.
  • To achieve accurate, efficient and long lasting performance, comparable with World’s best, Astra’s Optics are sourced from reputed USA & European optics manufacturers.
  • We assure our customers of a complete laser lithotripsy solution for all procedures at affordable cost.
  • Customers will be immensely benefited in the longer run as the cost of the spares & services will be quite low.
  • Wide band of power from minimum 1.6 Watts to maximum 36 Watts facilitates versatile laser lithotripsy procedures.
  • Accurate & optimum laser spot makes the stone fragmentation efficient & damage free.
  • Extra cooling capacity chillers assure long duty cycles in tropical and subtropical weather.

 

Advantages

  • High power output of 35W for effective and rapid stone fragmentation.
  • Minimally invasive treatment with reduced tissue damage.
  • Efficient cooling system for consistent performance during long procedures.
  • Expertly designed by industry professionals for precision and reliability.
  • User-friendly interface for easy operation and minimal learning curve.
  • Optimal cost-effectiveness without compromising on quality.

 

Read More...


Request to Call


Business Type Manufacturer, Exporter, Supplier
Application Hospital
Control Unit Power Supply 230 VAC, 50 Hz
Control Unit Working Pressure 1.8 to 4 Kg/Cm2K
Control Unit Maximum Input Pressure 6 Kg/Cm2
Control Unit Pressure Source Pressurised oxygen/Compressed air
Hand Piece Dimension (Dia x length) 24x180mm
Hand Piece Weight 150 gms
Air Compressor Input Voltage 230V
Air Compressor Output Pressure 4 kg/cm2
Air Compressor Airflow 30 liter/min

Click to view more

The pneumatic lithotripter uses high-pressure air pulses to efficiently break kidney and ureteral stones during urological procedures. Its compact design ensures precise stone fragmentation with minimal tissue damage and heat generation.

 

Features

  • Calculiclast®, the pneumatic lithotripter was designed and developed in India in 1994.
  • The device operates by generating high-pressure air pulses which are delivered through probe to fragment urinary stones. The mechanism is highly efficient, capable of breaking even larger stones into small fragments.
  • The precise and minimum forward movements of the probe minimize stone flying ensuring minimal tissue damage.
  • Adjustable pneumatic pressure allows the user to adjust the power of the blast.
  • The device is provided with special accessories and probes for fragmentation of renal and bladder stones. Adaptors can be provided to connect the machine to central connection.
  • The device comes with an option of oil less, noiseless computer mounted on a powder coated trolley.

 

Probes

  • 0.8mm, 1mm, 1.2mm probes for ureterorenoscopy
  • 1.5mm probes for bladder stones
  • 2mm probes for renal stones

 

Regulatory Approval

  • Approved by CDSCO for manufacturing license, adhering to national regulatory requirements for medical devices.
  • Safety Compliance: Certified according to EC 60601-1, ensuring the highest standards for electrical medical equipment safety.

 

Advantages of Calculiclast

  • Pneumatic energy breaks down the stones effectively into smaller, passable fragments.
  • The precise pneumatic mechanism allows to target the stones with minimal impact on surrounding tissues.
  • Compared to other stone-breaking technologies, pneumatic lithotripters are more affordable, making them accessible to a broader range of healthcare facilities.
  • The compact design is ideal to use in clinical settings as it allows for easy transportation and setup.
  • ​Designed with simplicity and ease of use in mind, it allows for straightforward operation by medical professionals, requiring minimal training.
Read More...


Request to Call


Business Type Manufacturer, Exporter, Supplier
Control Unit Power Supply 230 VAC, 50Hz
Control Unit Working Pressure 1.8 to 4 Kg/Cm2K
Control Unit Maximum Input Pressure 6 Kg/cm2
Control Unit Pressure Source Pressurised oxygen/Compressed air
Hand Piece Dimension (Dia x length) 24x180mm
Hand Piece Weight 150 gms
Air Compressor Input Voltage 230V
Air Compressor Output Pressure 4 kg/cm2
Air Compressor Airflow 30 liter/min

Click to view more

Features 

  • The Digital Pneumatic Lithotripter is a state-of-the-art device designed for efficient and precise fragmentation of kidney and ureteral stones. 
  • Equipped with an intuitive LCD display, it provides a user-friendly interface for seamless operation and real-time monitoring. 
  • The device enables urologists to pre-define programs with specific pressure and frequency settings, automatically configuring the parameters upon selection for effortless use.
  • The electro-pneumatic regulator ensures precise pressure setting resulting in accurate power delivery
  • The system includes automatic low-pressure detection for enhanced safety and reliability during procedures. 
  • Compact, portable, and energy-efficient, the lithotripter is ideal for modern urological practices. Built with durability and ease of maintenance in mind, it represents a perfect blend of cutting-edge technology and practical functionality, setting a new standard in pneumatic lithotripsy.

 

Probes

  • 0.8mm, 1mm, 1.2mm probes for ureterorenoscopy
  • 1.5mm probes for bladder stones
  • 2mm probes for renal stones

 

Advantages

  • Offers a clear and intuitive interface for easy operation and real-time monitoring of system parameters.
  • Enables personalized settings for various treatment protocols, enhancing flexibility and efficiency.
  • Delivers precise and consistent control of pneumatic pressure for effective and reliable stone fragmentation.
  • Lightweight and ergonomically designed for easy transport and setup in diverse clinical environments.
Read More...